1.適用范圍Scope
本規(guī)范適用于蘇州鼎時(shí)電子有限公司生產(chǎn)的自控制保護(hù)器。
This Specification applies to the fuse linked with heater which made by LANSON ELECTRONICS Corporation.
2.適用安全標(biāo)準(zhǔn)Applicable Safety Standards
UL248-1,Ul248-14。
3.UL認(rèn)證 UL File Number
E221465.
4.外形與回路圖 Dimensions and Circuit Chart
4.1外形圖 Dimensions
(4)產(chǎn)品的尺寸代碼,J表示4.0mm×3.0mm×0.85mm,H表示5.4mm×3.2mm×1.35mm,K表示9.5mm×5.0mm×2.0mm等。
Dimension code of the product, J means 4.0mm × 3.0mm × 0.85mm, H means 5.4mm × 3.2mm × 1.35mm, K means 9.5mm × 5.0mm × 2.0mm, etc.
5.規(guī)格 Rating
型號(hào) Part number |
額定電流Current Rating |
額定電壓★ Voltage Rating |
最大阻斷電流Max. Breaking capacity |
保險(xiǎn)絲電阻Fuse DCR |
適用電芯數(shù)Cells in series |
動(dòng)作電壓范圍Operating Voltage |
A |
VDC |
A |
m Ω |
cell |
V |
|
SCP30A5H |
30 |
62 |
80 |
0.5-2.5 |
5 |
17.10~23.50 |
★額定電壓是保險(xiǎn)絲組件可以安全阻斷的最大電壓值,不是發(fā)熱器組件的動(dòng)作電壓。
★Rated voltage is the maximum voltage that the fuse can block, not the action voltage of the heater assembly.
6.環(huán)境性能 Environmental Characteristics
(1)產(chǎn)品中使用的各種材料的鹵素含量如下表所示。
Contents of halogens used in each material for the product are as follows.
鹵素 Halogen substance |
含有量 Content |
氯(CL) Chlorine(CL) |
≤ 900ppm (0.09%) |
溴(Br) Bromine(Br) |
≤ 900ppm (0.09%) |
總和(氯(CL)+溴(Br)) Total concentration of chlorine (CL) + bromine (Br) |
≤ 1500ppm (0.15%) |
(2)本規(guī)范中描述的產(chǎn)品符合ROHS指令。BOM表中的合金、焊料、一些電子漿料含有鉛,但都符合ROHS指令的高鉛豁免相關(guān)規(guī)定。。
The product described in this specification complies with the ROHS Directive. BOM table contains the alloy, solder, some electronic slurry, including lead, but these are exempted from ROHS requirements.
7.性能Characteristics
7.1.測(cè)試一般條件 General Conditions of Measurement
除非特別指定,否則按以下環(huán)境條件進(jìn)行測(cè)量。
In the absence of additional test environmental standards, the test environmental standards are as follows;
環(huán)境溫度:5~35℃;
相對(duì)濕度:45~85%RH;
氣壓:86~106KPa。
Ambient temperature: 5 to 35℃.
Relative humidity: 45 to 85%RH.
Air pressure:86 to 106kPa.
如果在判定產(chǎn)生疑義的情況下,按照以下條件進(jìn)行測(cè)定。
If you have any questions about the test results, please follow the following environmental standards.
環(huán)境溫度:20±2℃;
相對(duì)濕度:60~70%RH;
氣壓:86~106KPa。
Ambient temperature: 20±2℃.
Relative humidity: 60 to 70%RH.
Air pressure: 86 to 106kPa
7.2.電氣的性能 Electrical Characteristics
No. |
項(xiàng)目 Items |
測(cè)定條件 Conditions |
技術(shù)規(guī)格 Specifications |
1 |
熔斷時(shí)間 Clearing time |
產(chǎn)品參照《電壓動(dòng)作特性測(cè)試方法》連線,向測(cè)試板(4-1端或者4-3端)施加對(duì)應(yīng)規(guī)格的動(dòng)作電壓 Apply the operating voltage to the heater. For other procedures, refer to《Voltage action characteristic test method》. |
保險(xiǎn)絲組件一分鐘內(nèi)熔斷。 The fuse shall be melt Within 1min.
|
產(chǎn)品參照《電流動(dòng)作特性測(cè)試方法》連線,向測(cè)試板(1-3端)施加兩倍額定電流。 Energize both ends of the fuse with twice the rated current. For other procedures, refer to《Current action characteristic test method》. |
|||
2 |
通電容量 Current carrying capacity |
產(chǎn)品參照《溫升測(cè)定方法》連線,向保險(xiǎn)絲組件(1-3端)施加額定電流。 Energize the rated current at both ends of the fuse. For other procedures, refer to《Temperature Rise characteristic test method》. |
保險(xiǎn)絲組件1小時(shí)內(nèi)沒有熔斷。 No melting within 1 hour |
注:
電氣性能受基板熱容量、零件、圖案寬度等條件的影響。因此,請(qǐng)將產(chǎn)品安裝在客戶實(shí)際使用的基板上確認(rèn)特性。
Electrical Characteristics is influenced by thermal capacity of PCB, parts, pattern width, and so on. Therefore you should check it on your PCB.
7.4.耐久性能 Endurance Characteristics
NO |
項(xiàng)目 Items |
測(cè)定條件 Conditions |
規(guī)格 Specifications |
1 |
高溫 Dry heat |
在100±5℃環(huán)境保持6小時(shí)后,常溫常濕條件下放置1小時(shí)后進(jìn)行測(cè)量。 The fuse shall be stored at a temperature of 100 ± 5 ℃ for 6h. And then it shall be subjected to standard atmospheric conditions for 1h, after which its measurement shall be made. |
沒有外形變形,上蓋脫落等異常,滿足電氣性能。 Without deformation of case or excessive looseness of caps. Electrical characteristics shall be satisfied. |
2 |
低溫 Cold |
在-20±3℃環(huán)境保持500小時(shí)后,常溫常濕條件下放置1小時(shí)后進(jìn)行測(cè)量。 The fuse shall be stored at a temperature of -20±3℃ for 500h. And then it shall be subjected to standard atmospheric conditions for 1h, after which its measurement shall be made.
|
|
3 |
濕熱 Damp heat |
在40±2℃、相対濕度90~95%RH環(huán)境保持250小時(shí)后,常溫常濕條件下放置1小時(shí)后進(jìn)行測(cè)量。 The fuse shall be stored at a temperature of 40±2℃with relative humidity of 90 to 95%RH for 250h. And then it shall be subjected to standard atmospheric conditions for 1h, after which its measurement shall be made. |
|
4 |
耐久測(cè)試 Endurance test |
給產(chǎn)品通電100A電流5ms,斷開995ms為一個(gè)周期,一起循環(huán)一萬(wàn)個(gè)周期。 100A be carried for a period of 5ms. The current is there switched off for a period of 995ms.this cycle is repeated 10,000 times. |
外形無(wú)明顯變形、破損,保險(xiǎn)絲組件沒有熔斷。 Without damage such as deformation or disconnection of fuse element. |